About TanklessCalc
Size a tankless water heater by flow rate and temperature rise, and see what a unit really delivers in winter rather than the headline number on the box.
Who writes and checks this site
Alex Motor, Editor and calculator builder. Alex builds and maintains the calculators on TanklessCalc and checks each guide against the sources it cites. Corrections go to boldwebdevelopment@gmail.com.
The figures in the guides are computed from the same code and data the site's tools use, so a guide cannot disagree with the tool it explains. A corrected guide shows the date it was updated.
What the tools are built on
- A tankless heater's advertised maximum flow rate is measured at a small temperature rise, conventionally about 35 degrees Fahrenheit, so the same unit delivers roughly half that at a 70 degree rise.
- Heating water takes 500.724 BTU per hour for every gallon per minute and every degree Fahrenheit of rise, derived from a gallon of water weighing 8.3454 pounds.
- Temperature rise is the target temperature minus the incoming cold water temperature, and incoming water runs about 40 degrees Fahrenheit in Minnesota against 72 in Florida.
- A typical shower draws about 2.1 gallons per minute and a bathtub filler about 4, which is the largest single draw in a house.
- Whole-house electric tankless units draw enormous current: 27 kilowatts at 240 volts is 112.5 amps, which is why they are uncommon in cold climates.
- Two simultaneous 2.1 gallon per minute showers at an 80 degree rise need about 181,000 BTU of input at 0.93 efficiency, so only a 199,000 BTU condensing unit covers them, and adding a kitchen tap exceeds any single residential gas tankless unit.
How this site is built
It is a static website. Every page is a pre-built file served from a content delivery network, and every calculation runs in your browser using JavaScript you can read. There is no account system, no server holding your inputs, and no paid API being called while you wait.
How it is funded
Affiliate links, disclosed where they appear.
Contact: boldwebdevelopment@gmail.com.
Where the numbers come from
- Federal maximum flow rates for showerheads (2.5 GPM) and faucets (2.2 GPM)
- Rinnai RU-series (Sensei) specification sheet and Rinnai RV53E manual
- Rheem RTEX specification sheet TKE-101 and Stiebel Eltron Tempra engineering specification sheet
- National Electrical Code 240.6(A) breaker sizes and Table 310.16 copper ampacity, as published in Cerrowire’s ampacity chart
What this site does not do
- It does not collect your data, and has no way to.
- It does not give professional advice. See the disclaimer.
- It does not claim to be complete: where a question is out of scope, the page says so.
Independence
This site is not affiliated with, endorsed by, or connected to any government agency, standards body, manufacturer or retailer mentioned in its content. Errors are the operator's responsibility.